CATL EnerOne+ 407.3 kWh Energy Storage
$35200,00
CATL EnerOne+ 407.3 kWh Outdoor Liquid Cooling Rack battery for Solar Storage Design life
20 years Up to 10,000 cycles.
Description
CATL EnerOne+ 407.3 kWh Outdoor Liquid Cooling Rack Standard current configuration using 306 Ah LFP cells.
Designed for solar + storage, microgrids, peak shaving, backup power, and utility applications. The EnerOne+ builds on the original EnerOne platform with higher energy density, improved thermal management, and updated cell technology
The EnerOne+ Rack consists of following parts : batteries, BMS, FSS and TMS, which are integrated together
to keep the normal working of the Rack.
Specifications
| Features | Description |
|---|---|
| Battery Chemistry | Lithium Iron Phosphate (LFP) |
| Energy Capacity | 407.3 kWh nominal |
| Cell Capacity | 306 Ah |
| Configuration | 1P416S |
| Rated Voltage | 1331.2 VDC |
| Cooling | Intelligent variable-frequency liquid cooling |
| Ingress Protection | IP66 outdoor enclosure |
| Corrosion Protection | C5 corrosion-resistant cabinet for harsh environments |
| Dimensions (L × W × H) | 1344 × 1390 × 2344 mm |
| Weight | ~3,650 kg |
| Design Life | Up to 20 years |
| Cycle Life | Up to 12,000 cycles (optional long-life cell configuration) |
| System Compatibility | 600–1500 V DC PCS architectures |
| Installation | Factory-assembled outdoor cabinet |
Advantages
1. Liquid Cooling
Unlike air-cooled battery cabinets, EnerOne+ uses a liquid cooling system that keeps cell temperature differences very small, improving:
- Battery life
- Capacity retention
- Safety
- Charging/discharging efficiency
The original EnerOne maintained cell temperature differences within about 3°C, contributing to its long service life.
2. CATL CTP (Cell-to-Pack)
CATL’s Cell-to-Pack technology removes unnecessary module structures, resulting in:
- Higher energy density
- Fewer electrical connections
- Lower failure rates
- Reduced weight
3. High Safety
EnerOne+ includes multiple protection layers:
- Cell monitoring
- Module monitoring
- Rack-level BMS
- Cabinet-level BMS
- Thermal runaway detection
- Aerosol/fire suppression
- Pressure relief vents
- Electrical isolation
- Fault diagnostics
CATL also incorporates its No Propagation (NP) technology to reduce the risk of thermal runaway spreading between cells.
4. Long Lifetime
Typical performance :
- Up to 10,000 charge/discharge cycles
- Around 20 years design life
For one full cycle per day :
- 365 cycles/year
- 10,000 cycles ≈ 27 years (actual service life depends on temperature, depth of discharge, and operating profile).
5. Flexible Integration
The cabinet is compatible with DC systems from 600 V to 1500 V, allowing integration with many third-party PCS brands, such as:
Sungrow, Sinexcel, Kehua, SMA, Power Electronics, Gamesa Electric, Delta ABB
This flexibility enables system integrators to optimize cost and performance.
6. Applications
For Commercial & Industrial (C&I)
- Manufacturing plants
- Warehouses
- Commercial buildings
- Shopping malls
- Hotels
- Hospitals
- Universities
- Airports
Typical objectives :
- Peak shaving
- Demand charge reduction
- Time-of-use energy arbitrage
- Backup power
For Solar Storage
A common configuration :
- 300–600 kWp PV system
- One 407.3 kWh EnerOne Plus 2.0 cabinet
- 100–250 kW PCS
- EMS for PV optimization
Benefits :
- Higher self-consumption of solar energy
- Reduced grid imports
- Improved return on investment
For EV Charging Hubs
- DC fast charging stations
- Bus depots
- Fleet charging
- Truck charging
It can :
- Reduce peak demand charges
- Buffer high-power charging loads
- Improve grid stability
CATL EnerOne+ for Microgrids
- Industrial campuses
- Remote communities
- Islands
- Mining sites
- Military installations
It supports grid-connected, islanded, and hybrid operating modes when paired with a suitable PCS and EMS.
Data Centers & Critical Loads
The EnerOne+ can supplement UPS systems by providing:
- Extended backup duration
- Peak demand management
- Renewable energy integration
- Enhanced power resilience
Discharge Performance :
| PCS Rating | Approx. C-rate | Discharge Time | Typical Application |
|---|---|---|---|
| 100 kW | 0.25C | ~4.1 hours | Solar energy shifting |
| 125 kW | 0.31C | ~3.3 hours | Commercial buildings |
| 150 kW | 0.37C | ~2.7 hours | Peak shaving |
| 200 kW | 0.49C | ~2.0 hours | Standard C&I ESS |
| 250 kW | 0.61C | ~1.6 hours | High-power applications |
EnerOne+ Plus 2.0 372.7 kWh Datasheet : Read More
5 years standard CATL Warranty.
Covers
Commercial BESS warranties commonly include:
- Battery cabinet defects
- Battery module defects
- BMS hardware
- Cooling system
- Factory-installed wiring
- Manufacturing defects
- Capacity retention guarantee (performance warranty)
Warranty Conditions
To maintain warranty coverage, the system is generally required to operate within specified limits, such as:
- Ambient temperature within the specified range
- State of charge (SOC) and depth of discharge (DOD) limits
- Maximum charge/discharge C-rate
- Installation by an authorized integrator
- Remote monitoring enabled
- Scheduled preventive maintenance
- Approved PCS and EMS integration