CT-4008-5V20A-A Neware Battery Cycler
$3200,00
CT-4008-5V20A-A / BTS4000-5V20A Neware Battery Cycler 18650 – Polymer Lithium Test Equipment Charge – Discharge. Fast Respon Time.
Description
BTS4000-5V20A
CT-4008-5V20A-A Neware Battery Cycler 18650, Polymer Lithium Testing Equipment. 10Hz 18650 Battery Charger Capacity Tester, Neware battery charge discharge.
Features :
1. Less than 20ms Response Time to Meet Rapidly Changing Power Requirements .
2. 0.1 percent Full – scale Accuracy for Current and Voltage .
3. 10Hz Data Acquisition Frequency , 100Hz Optional .
4. 500ms Minimum Pulse Width More Than 1 Million Records Can Be Processed .
BTS4000-5V20A CT-4008-5V20A-A Specifications Datasheet :
| Project index | Parameter index | |
| Input Power | AC 110V ±10% / 60Hz | |
| resolution | AD:16bit;DA:16bit | |
| Input Resistance | ≥1MΩ | |
| Input Power | 1418W | |
| Channel Features | Constant Current Source and Constant Voltage Source with Independent pairs of Closed-loop Structure | |
| Channel Control Mode | Independent Control | |
| Voltage | Per Channel Voltage Range | 25mV~5V |
| Discharge Min Voltage | 2.5V | |
| Accuracy | ± 0.1% of FS | |
| Stability | ± 0.1% of FS | |
| Current | Per Channel Current Range | 0.1A~20A |
| Accuracy | ± 0.1% of FS | |
| Stability | ± 0.1% of FS | |
| Power | Per Channel Output Power | 0.04A |
| Stability | ± 0.2% of FS | |
| Time | Current Response Time | 20ms (0-Full Range) |
| Step Time Range | ≤(365*24 )hour/step,
Time Form Support 00:00:00(h、min:s、ms) |
|
| Data Recording | Record Condition | Time△t:100mS |
| Voltage△U:10mV | ||
| Current△I:40mA | ||
| Record Frequency | 10Hz | |
| Charge | Charge Mode | Constant Current Charge、Constant Voltage Charge、
Constant Current and Constant Voltage Charge、CPC |
| End Conditon | Voltage、Current、Relative Time、Capacity、-△V | |
| Discharge | Discharge Mode | CCD、CPD、CRD |
| End Condition | Voltage、Current、Relative Time、Capacity、 | |
| Pulse | charge | CCC |
| Discharge | CCD | |
| Min Pulse Width | 500ms | |
| Automated Switch | Automated swith from charge to discharge for each pulse | |
| End Condition | Voltage, Test Time | |
| Cycle | Loop Measure Range | 1~65535 times |
| Max Steps Per Loop | 254 | |
| Nested Loop | Nested loop Function,Max Support 3 Layers | |
| Protection | Software Protection | l Power-down Data Protection |
| l Off-line Testing Function | ||
| l Setting Protection Condition,Setting Parameter:Low Voltage limit、Upper Voltage limit、Low Current limit、Upper Current limit、Delay Time | ||
| Hardware Protection | Additional Anti-reverse Protection Model | |
| Voltage and Current Testing Sample | 4-wire connecting | |
| Noise | <85dB | |
| Database | MySQL Database | |
| A Means of Communication of Upper Machine | TCP/IP Protocol | |
| Data Output | EXCEL、TXT、Graph | |
| Communication Interface | Ethernet Port | |
| Per Unit Main Channels No. | 8 | |
| Dimensions | 3U3F,480*730*130(mm) | |
Equipment Working Environment
| Project index | Parameter index |
| Working Temperature Range | 0℃~40℃ |
| Storage Temperature Range | -10℃~50℃ |
| Working Environment Relative Humidity Range | 30% ~ 80% RH |
| Storage Environment Relative Humidity Range | 30% ~ 90% RH |








Reviews