CM200DX Inverter Cascadia Motion
Original price was: $6420,00.$5600,00Current price is: $5600,00.
New for Sale CM200DX Inverter Cascadia Motion Controller.
Description
Newest inverter is the CM200DX Inverter Cascadia Motion, packing the punch of a PM150 but being smaller volume and lighter weight than a PM100. Also features HVIL, pluggable connectors and an EMI filter!
For full product details, see the datasheet below.
CM200DX Inverter Features:
4 (0-5V) Analog Inputs
2 RTD inputs PT100/1000
4 Digital Inputs 4-STG
2 High Side Driver Outputs
2 Low Side Driver Outputs
1 Resolver Interface
1 Sin-Cos Encoder Interface (-SP Option)
2 CAN 2.0A/B Ports 125kb-1Mb adjustable rate and offset
RS232 Programming and Diagnostic Connection
Rosenberger Power Connectors
Integrated DC-Link EMI Filter
Designed to ISO16750 heavy vehicle climatic, mechanical, and environmental requirements
ISO20653 high pressure wash rated IP6K9K / IP67
Easy to use CAN-based network node
Custom .dbc messaging J1939 compatible CAN messages available
Extensive feedback broadcast messaging for datalogging
PC-based setup and programming tools available free
Robust, fault-tolerant IGBT power stage HVIL Interlock on connectors
Command Safety Watchdog
Variable PWM Rate
CM200DX Inverter Cascadia Motion Spec Sheet
| CM200
DC Voltage – operating DC Overvoltage Trip Maximum DC Voltage – non- operating Motor Current Continuous |
DX | DZ | Units |
| 50-480 | 200-840 | VDC | |
| 500 | 860 | VDC | |
| 500 | 900 | VDC | |
| 300 | 200 | A | |
| Motor Current Peak * | 740 | 400 | Arms |
| Output Power Peak (elect) * | 225 | 225 | kW |
| DC Bus Capacitance | 650 | 255 | μF |
| Size and Volume | 330 x 188 x 97 / 3.9 | mm / L | |
| Weight | 6.75 | kg | |
| Active Discharge via motor | < 1 | sec | |
| winding to <50V | |||
| Passive Discharge (internal | < 120 | sec | |
| resistor) to <50V | |||
| Vehicle System Power | 9 .. 32
(12V & 24V systems) |
VDC | |
| Inverter PWM Frequency | 12
(6 .. 16 variable) |
kHz | |
| Operating Temperature Range | – 40 .. +80, (derate | °C | |
| – coolant water | to zero 80 .. 100) | ||
| Coolant Flow Rate | 12
(3 GPM min) |
LPM | |
| Coolant Pressure Drop (60°C | 0.3 (30kPa / 4.3psi) | bar | |
| coolant / 12 LPM) | |||
| Maximum Coolant Pressure | 3 (300kPa / 45psia) | bar | |
| (absolute) | |||
| Operating Shock (ISO 16750-3, | 500 (50g), pending | m/s2 | |
| Test 4.2.2.2) | |||
| Operating Vibration (ISO | 57.9 (6grms), | m/s2 | |
| 16750-3, 4.1.2.7 Test VII) | pending | ||
| EMC compatibility | IEC61000 /
CISPR-25 pending |
||
| Compatible Conductor Sizes | 16, 25, 35, 50 | mm2 | |